Made to order.
For variants available to order, we confirm the delivery
date and shipping cost by email after your order.
Shipping is not included in the amount paid at checkout.
Externally triggered pyrotechnic fuse for high-voltage DC circuits. Fired by a signal from the management system, it severs the busbar in under 2 ms at any current, and self-triggers above 250 °C.
Used in high-voltage BMS, traction inverters, battery packs and energy storage capacitors — in electric vehicles, wind turbine converters and photovoltaic systems.
1000 V DC · 400 A on a 120 mm² busbar at 85 °C · 16 kA breaking capacity, no minimum breaking current · −40 °C to +85 °C · bolted M6, 6 ± 1 N·m.
CE marked, RoHS compliant, UL94-V0 flame rating. Qualified to LV124 and LV16.
Specifications
Brand
Sinofuse
Product family
Pyro Fuses
Series
SFH-400-C
Rated voltage
DC 1000 V
Current type
DC
Breaking capacity
16 kA @ DC 1000 V / 35 µH
Trigger type
External
Action time
≤ 2 ms
Trigger current
≥ 1.75 A / 0.5 ms or ≥ 1.2 A / 2.0 ms
Non-triggering current
≤ 0.4 A / 10 s
Allowable detection current
≤ 100 mA
Igniter resistance
1.7 to 2.3 Ω
Self-triggering temperature
≥ 250 °C
Mounting type
Bolted
Operating temperature range
−40 °C to +85 °C
Maximum altitude
5500 m
Flame retardant rating
UL94-V0
Reference standards
LV124 · LV16
Certifications
CE
RoHS compliant
Yes
Application sectors
Automotive, Wind energy, Photovoltaic, Energy storage
Typical applications
Short-circuit and overload protection for EV drive systems, power conversion systems, batteries, energy storage capacitors and inverters. Designed for high-voltage BMS applications. Rated current given for a 120 mm² busbar at 85 °C. Insulation resistance ≥ 100 MΩ between busbar and igniter, ≥ 50 MΩ between busbar and housing, ≥ 10 MΩ between busbar sections after break.